Environmental test chambers, also known as temperature and humidity environment chamber, climate chamber, is commonly used in laboratories and factories for environmental simulation systems and devices. Environmental test chamber can simulate temperature, humidity, air pressure, light, vibration, corrosion and other different environmental conditions. The test chamber is usually composed of control system, heating system, refrigeration system, humidity control system, air pressure control system, lighting system, vibration system, corrosion system and so on. According to the test requirements, different environmental parameters can be selected for adjustment to simulate the required environmental conditions. There are many kinds of environment boxes. For people who are not familiar with environment boxes and who buy them for the first time, choosing environment boxes is a very headache. Therefore, through this article, I will help you to understand how to choose the right temperature and humidity environment room? In addition, if you want to know more about the standards and applications of temperature and humidity boxes, you can contact our company's technical staff. We will give you a satisfactory answer as soon as possible.

1. Requisitos de teste

Em primeiro lugar, é necessário definir o tipo de produto, parâmetros de teste e padrões de teste para selecionar a câmara de teste ambiental que atenda aos requisitos de teste. É importante analisar seus requisitos de teste em detalhes ao selecionar a câmara de teste ambiental certa para seus requisitos. Primeiro, considere o tipo de ambiente que você está testando e se ele tem condições extremas, como temperatura, umidade ou altitude. Em segundo lugar, considere sua indústria, como: indústria de produtos eletrônicos e elétricos: produtos eletrônicos e elétricos precisam passar por baixa temperatura, alta temperatura, ciclo de alta temperatura, impacto de alta e baixa temperatura, névoa salina, calor e umidade, vibração, queda e outros testes, a fim de avaliar sua confiabilidade e durabilidade em diferentes ambientes.

2. Seleção da faixa de temperatura

A faixa da câmara de teste de temperatura estrangeira é geralmente -73 ~ + 177 °C ou -70 ~ 180 °C. Os fabricantes nacionais de produtos são principalmente -80 ~ + 130 °C, -60 ~ + 130 °C, -40 ~ + 130 °C, alta temperatura a 150 °C. Essas faixas de temperatura geralmente atendem às necessidades da maioria dos testes de temperatura militares e civis domésticos.

3. Faixa de umidade

Select the appropriate humidity range according to the test requirements. Some test chambers can simulate very high humidity (such as 95%RH or higher), while others are suitable for very dry environments (such as 0%RH) where the higher the temperature, the lower the relative humidity for the same absolute moisture content. For example, the absolute moisture content is 5g/kg, and when the temperature is 29℃, the relative humidity is 20%RH. When the temperature is 6°C, the relative humidity is 90% RH. When the temperature drops below 4℃ and the relative humidity exceeds 100%, condensation will occur in the box. The temperature index of environmental test chamber at home and abroad is generally 20~98%RH or 30~98%RH. If the constant temperature and humidity box does not have a dehumidification system, the temperature ranges from 60 to 98%. The chamber can only be used for high humidity tests, but it is much cheaper. It is important to note that the humidity indicator should be followed by the corresponding temperature range or minimum dew point temperature. Because relative humidity is directly related to temperature.

4. Precisão do controle

The control precision of environmental test chamber has important influence on the accuracy and reliability of test results. The appropriate control precision needs to be selected according to the test requirements. Usually, the more accurate the control, the higher the price of the equipment. The relative humidity deviation of environmental test chamber should be ±2%RH or ±3%RH. In order to meet the requirements of temperature control accuracy, the temperature fluctuation is generally less than ±0.2℃; otherwise, it is difficult to meet the requirements of humidity control accuracy

5. Velocidade do vento

De acordo com as normas relevantes, ao realizar testes ambientais, a velocidade do vento na caixa de teste de temperatura e umidade deve ser inferior a 1,7 m/s. Mas se a necessidade para a câmara e a temperatura, a umidade, a vibração e os outros fatores rápidos do teste ambiental detalhado da câmara, aceleram o caudal do ar de circulação no tanque. A velocidade do vento é geralmente de 2 ~ 3 m / s. Para a maioria dos requisitos gerais de teste, a velocidade do vento na câmara de teste ambiental é geralmente entre 0,5 m/s e 2,5 m/s, e a velocidade do vento nessa faixa pode atender à maioria dos requisitos de teste. Por exemplo, para o teste de produtos eletrônicos e elétricos, a faixa comum de velocidade do vento é de 0,5 m/s a 1,5 m/s; Para testes de autopeças, uma faixa comum de velocidade do vento é de 1,5 m/s a 2,5 m/s.